Description
Niotech Transformers supplies three-phase, oil-immersed substation transformers for utility and industrial substations. Each unit is built to the project specification, with throat or bus connections arranged per project.
The standard configuration is three-phase, aluminum windings, Type I mineral oil, ONAN cooling, 65°C average winding temperature rise, 60 Hz, and ±2 × 2.5% full-capacity taps, in a sealed tank. Other arrangements are available as options, confirmed per project.
These transformers are typically applied in utility substations and industrial plants. Other primary voltages are available — contact us. Final ratings, accessories, lead time, and warranty are confirmed per project and stated in the written quotation.
Options
Available options, confirmed per project. Tell us what the installation requires when you request a quotation.
- Copper windings
- Natural ester insulating fluid
- Fan cooling (ONAF) where applicable
- Other primary voltages
- Alternative throat or bus connections
- Special paint or enclosure finish
Specifications
The table reflects the capacities and voltages offered in the selector above, together with the standard construction. Other primary voltages are available — contact us. Final ratings are confirmed on the approval drawings for each order.
| Type | Three-phase substation, oil-immersed |
|---|---|
| Capacity | 300 kVA, 500 kVA, 750 kVA, 1,000 kVA, 1,500 kVA, 2,000 kVA, 2,500 kVA, 3,000 kVA, 3,750 kVA, 5,000 kVA, 7,500 kVA, 10,000 kVA |
| Primary voltage | 12.47 kV GrdY/7.2 kV; 13.8 kV Delta; 13.8 kV GrdY/7.97 kV; 24.94 kV GrdY/14.4 kV; 34.5 kV Delta; 34.5 kV GrdY/19.92 kV. Other primary voltages available — contact us. |
| Secondary voltage | 480Y/277 V; 4.16 kV GrdY/2.4 kV; 12.47 kV GrdY/7.2 kV; 13.2 kV GrdY/7.62 kV; 13.8 kV Delta; 24.94 kV GrdY/14.4 kV |
| Frequency | 60 Hz |
| Cooling | ONAN |
| Temperature rise | 65°C average winding rise |
| Windings (standard) | Aluminum |
| Insulating fluid (standard) | Type I mineral oil |
| Taps (standard) | ±2 × 2.5% full-capacity |
| Tank | Sealed tank |
| Connections | Throat or bus connections, arranged per project |
| Efficiency | Designed to DOE 2016 efficiency levels where applicable |
| Certification | Certification requirements confirmed per project |
| Lead time | Confirmed per project |
| Warranty | Confirmed per project |
Frequently asked questions
What does the starting price represent?
The starting price is a reference figure for the selected capacity and voltages in the standard configuration. Request a quotation for a firm price on your project.
What if my combination does not show a starting price?
Some capacity and voltage combinations are quoted individually. Select your configuration and use Contact Us for a Quote — or email us with the rating you need.
Can you supply a primary voltage that is not in the dropdown?
Yes. Other primary voltages are available. Contact us with the rating you need, and we will reply with a written quotation.
Can the unit be supplied with a different winding material, fluid, or cooling arrangement?
Yes. Copper windings, natural ester fluid, fan cooling (ONAF) where applicable, and the other options listed on this page are available, confirmed per project.
What are the lead time and warranty?
Lead time and warranty are confirmed per project and stated in the written quotation.
How should I request a quotation?
Use the button above to send the selected capacity and voltages, or email [email protected] with your specification, drawings, or nameplate data.
Ready to specify this transformer?
Send the selected capacity and voltages — or your drawings — and we will reply with a written quotation.